On-line Temperatrue Aging Chamber(Clean function)

Product description:

Feature

 

 

1.Class 10, 000 clean, to avoid contamination of the module or COB under test  

 

2. Support SFP/SFP+, XFP, QSFP28 and other encapsulation forms  

 

3. IIC communication, support 8472 protocol, 8077 protocol, 8436 protocol, etc  

 

4 Support single module current 0~1.5A, ±0.5%FS±2mA, can be used for different modules  

 

5 Configure different over-current protections  

 

6. It can monitor the working current of each module and automatically identify whether the module fails  

 

7.Failure judgment can be set . It can be customized.


Share to:
Other parameters

Equipment

On-line aging test chamber

Mode

HCON-280D-150-on line

Technique specification

Internal size

70 cm (W) x1625px (H) x1550px (D)*2

Internal capacity

280L*2 chambers

External size

3625px (W) x4750px (H) x2725px (D)

Temperature range

RT+30~120℃(no load

Temperature uniformity

±3℃;

Temperature fluctuation

±1℃;

Heating rate

3/min

Control system

22 inch touch screen

Communication interface

ETHERNET RJ45

Power supply

AC 3 phase 5 wire 380V 50Hz

Power

Within 10KW

Weight

500KG

1. Test texture and module interface

Layer

2 chamberseach chamber contains 42 circuit broad insidea total of 84 pieces.

Board module numbers

 

Each board contains 8 modules

 

Number of     modules that   can be accommodated

 

 

672 pieces

Optical module interface

IIC interfacecompatible IIC 8472IIC 8436

Optical module power

3.0V~3.5V Adjustable software, output fluctuation1%

 

Channel drive capacity

SFP+ module 300mA QSFP+module600mA over-current protect range 20~1000mA

Current detect accuracy

0.1mAdeviation3%

Voltage detect accuracy

4mVdeviation3%

Bracket thermistor

±2℃;

Others

Provide ESD/EOS monitoring of 3.3V module power supply.


3 Module monitoring software

 

 

Software function

1 Complete product power on, temperature control and monitoring;  

2 Display temperature, current, voltage, aging time, etc.  

3 Product aging state and software shutdown/start do not affect each other;  

4 After the software restarts, the current product aging status is displayed.  (Software hot start)  

5 Warning message is displayed when the software is shut down. 

Specific module monitoring data

Optical module voltage and current/Input voltage and current/drive board temperature/Tray temperature and optical module temperature/bias current/sending power; 

Control interface

22 inch touch screen HMI

 

4 Others

Power supply

3 Phase 5 wire AC380V±10%10KW

Environment

The temperature around the device shall be +20~+30.